Sign In | Join Free | My himfr.com
Home > Fixed Gas Detector >

CE Zetron MIC500S Outdoor Gas Leak Detector Electrochemical / IR Sensor

    Buy cheap CE Zetron MIC500S Outdoor Gas Leak Detector Electrochemical / IR Sensor from wholesalers
     
    Buy cheap CE Zetron MIC500S Outdoor Gas Leak Detector Electrochemical / IR Sensor from wholesalers
    • Buy cheap CE Zetron MIC500S Outdoor Gas Leak Detector Electrochemical / IR Sensor from wholesalers
    • Buy cheap CE Zetron MIC500S Outdoor Gas Leak Detector Electrochemical / IR Sensor from wholesalers

    CE Zetron MIC500S Outdoor Gas Leak Detector Electrochemical / IR Sensor

    Ask Lasest Price
    Brand Name : Zetron
    Model Number : MIC500S
    Certification : CE
    Price : USD 670-- 690/set
    Payment Terms : L/C, D/A, T/T, MoneyGram
    • Product Details
    • Company Profile

    CE Zetron MIC500S Outdoor Gas Leak Detector Electrochemical / IR Sensor

    MIC500S Fixed Gas Detector


    OVERVIEW

    MIC500S Series gas detector can be used in 24 hours continuous online monitoring of concentrations of multiple types of gases in the filed.The types for detection are more than 500 types.
    With a 4-20 mA analogue output, can be simply integrated into a Distributed Control System (DCS) to provide warnings.
    Simple to install service and calibrate, MIC500S requires no hot work permit and the PID sensor is accessible and changeable in a matter of seconds.
    User-friendly, reliable and cost-effective way to ensure safety, compliance and productivity.
    Strong, durable and explosion-proof shell is suitable for the use at a variety of hazardous places and harsh industrial environments, is widely used in the industries such as petroleum, chemical, metallurgy, refining, gas transmission and distribution, biochemical and pharmaceutical, and so on.
    FEATURES

    Infrared remote control

    ① Standard configuration includes the infrared remote control, it is possible for one-key operation via infrared remote control function key, which can achieve the operation without opening the cover under hazardous situations, such as: the functions like modification of the alarm point, density calibration, zeropoint calibration, noise reduction, restoring the factory setting, and so on.


    Powerful and convenient humanized function

    ① Multiple alarm modes, and multi-directional and threedimensional indication alarm states. It includes: 2 sets of relay switch output, sound & light alarm (optional configuration), and display screen visual alarm.Alarm types include: concentration alarm, and failure alarm.Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.

    ② Zero-point automatic tracking; long-term use will not be affected by the zero drift.

    ③ Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements.

    ④ Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration.

    ⑤ Data recovery function; in case of mis-operation, it is possible to select partial or full recovery.

    ⑥ Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.


    APPLICATION
    The detector is widely used in petroleum, chemical industry,environmental protection, metallurgy, refining, gas, biochemical medicine, agriculture, fire protection, Archaeology and other industries and places that need safety monitoring for toxicity and harmfulness, explosion prevention.
    SPECIFICATION

    Gas
    NO/NO2
    can be customized
    Range
    0-100ppm
    other ranges can be customized
    Size
    210×170×85mm (L×H×W)
    Weight
    1.8 Kg
    Installation method
    Pipeline Type
    Wall Mounting Type
    Display
    1.7-inch high-definition color screen
    Environment
    Temperature: -40 ℃ ~ + 70 ℃
    Humidity: ≤10 ~ 95% RH (regular)
    Approvals
    IP65; Exd Ⅱ CT6
    Accessories
    Manual, qualification certificate, warranty card, outer packaging box
    Working Voltage
    12 ~ 30VDC direct current, the standard power supply for a single equipment is 24V, DC stabilized voltage switching power supply of 1A or greater than 1A
    Working Method
    Fixed type installation, online detection, diffusion type measurement; and it is possible to select the measurement of pipeline type, flow-through type, and pump-suction type.
    Connecting Cable
    Adopted 4 ~ 20mA three-core shielding cable, adopted four-core for RS485, when the distance exceeded 100 meters, the single wire diameter ≥1.5mm; and the shielding layer will be connected to the earth.
    Optional items
    Alarms;Wireless Transmission;Pretreatment System; SD Card;
    Temperature and Humidity Measurement;
    Accessory for connection with computer for monitoring.
    Installation Type Accessories
    (Optional configuration)
    Wall mounting bracket, mounting clips for fixation on the pipes (1/2", 3/4" pipe),
    stainless steel threaded welding seat or flange to be installed on the pipeline (it is necessary to mark the flange or pipe size, such as DN50, DN15 ...),
    rain cover, 24VDC or 220AC sampling pump (sampling distance is 10 m),
    vacuum pump (sampling distance is 40 m),
    24V switching power supply, pressure reducing valve, flow meters

    Gases to be detected
    Range
    Accurancy
    Resolution
    Response time T90
    Oxygen gas ( O2 )
    0-30%Vol
    <±2%(F.S)
    0.01%Vol
    ≤10 seconds
    Nitrogen oxide ( NOX )
    0-100ppm
    <±2%(F.S)
    0.01ppm
    ≤30 seconds
    Chlorine gas ( CL2 )
    0-10ppm
    <±2%(F.S)
    0.001ppm
    ≤30 seconds
    Ammonia gas ( NH3 )
    0-100ppm
    <±2%(F.S)
    0.01ppm
    ≤30 seconds
    Hydrogen gas ( H2 )
    0-40000ppm
    <±2%(F.S)
    1ppm
    ≤30 seconds
    Nitrogen gas ( N2 )
    0-100%Vol
    <±2%(F.S)
    0.01%Vol
    ≤10 seconds
    Carbon monoxide ( CO )
    0-100ppm
    <±2%(F.S)
    0.1ppm
    ≤25 seconds
    Carbon dioxide ( CO2 )
    0-100%Vol
    <±2%(F.S)
    0.01%Vol
    ≤30 seconds
    Formaldehyde ( CH2O )
    0-100ppm
    <±2%(F.S)
    0.01ppm
    ≤30 seconds
    Ozone ( O3 )
    0-100ppm
    <±2%(F.S)
    0.01ppm
    ≤20 seconds
    Note: Not all gases and range are listed, if you need more information, please contact us.




    Quality CE Zetron MIC500S Outdoor Gas Leak Detector Electrochemical / IR Sensor for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Zetron Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)