    Brand Name : Zetron
    Model Number : Gasboard-9070
    Certification : CE, ISO13485, ISO9001
    Payment Terms : T/T, D/A, L/C, D/P, Western Union, MoneyGram
    Supply Ability : 1000 set/month
    Delivery Time : 3-7 days
    • Product Details
    • Company Profile

    High Temperature UV DOAS Flue Gas Monitoring System 0.1ppm Resolution For SO2 NO NH3

    High Temperature UV Flue Gas Monitoring System

    OVERVIEW

    High Temperature UV Flue Gas Monitoring System Gasboard-9070 is based on advanced UV-DOAS gas analysis technology, which can simultaneously measure the concentration of SO2, NO, NH3 and other gases. It adopts multiple reflection chamber to reach a lower limit of detection. The system adopts high temperature tracing on whole sampling circuit to ensure high measurement accuracy, that can be widely used to monitor the flue gas from industrial stacks or stationary pollution source before and after desulfurization and denitrification, and accurately reflect the conditions of ammonia escaping.


    FEATURES

    • Adopt UV-DOAS technology to measure SO2, NO, NH3 gas concentration simultaneously with high accuracy.
    • Using multiple reflection gas chamber to provide ultra-low range measurement and low detection limit.
    • High temperature tracing on entire gas flow path, adopting low-adsorption materials and processing techniques to effectively avoid the loss of SO2 and NH3.
    • Extractive measurement method, not affected by dust, temperature, and pressure fluctuations in the flue.
    • Built-in automatic correction algorithm to eliminate interference from other gas components.
    • Automatic calibration design, easy for operation and maintenance.
    • Widely applicable on different applications, not restricted by on-site installation conditions.


    SPECIFICATION

    Performance Parameters
    Measuring ComponentSO 2 , NO, NH 3
    Measuring PrincipleUV-DOAS
    Measurement RangeSO 2 : 1000mg / m 3 ; NO: 100mg / m 3 ; NH 3 : 20mg / m 3
    (Outlet of denitration)
    SO 2 : 50mg / m 3 ; NO: 50mg / m 3 ; The NH 3 : 20mg / m No 3
    (Outlet Of a stack)
    Precision≤± 2%F.S.
    Resolution0.1ppm
    Repeatability≤1%F.S.
    Response TimeT 90 ≤60s
    Working Parameters
    Ambient Temperature(0~50)°C
    Power SupplyAC220V, 800W
    Purge Gas Source(0.4~0.8)MPa compressed air
    Interface Signals
    CommunicationRS485, RS232
    Output Mode4 channels 4~20mA output
    8 channels relay output

    APPLICATION

    Gas concentration monitoring before and after desulfurization and denitrification of industrial chimneys and stationary sources of flue gas, including:
    . coal-fired power plants
    . Aluminum plants
    . Steel plants
    . Smelting plant
    . Waste-to-energy plants
    . Cement plants
    . Chemical plants and etc.


    High Temperature UV DOAS Flue Gas Monitoring System 0.1ppm Resolution For SO2 NO NH3


    FAQ

    Q: What is your terms of payment ?
    A:We accept trade assurance, western union ,Visa master card and tt.
    Trade assurance can protect you, when you confirm the product then the money into my account.

    Q: When do you reply to messages?
    A: We will reply you for your inquiry in 24 hours.

    Q: What is the warranty for your product ?
    A: Warranty: 12 months, Lifetime maintenance

    Q: When do you send the products? And how do you send it ?
    A: For the small order, we will send out the goods with 5 days,If have stock ,we will send immediately.
    We send them by ups, fedex, tnt or dhl. For big order, normal is 20 days will finish.

    Q:Do you accept OEM or revised logo, color, model, size?
    A:Yes, we accept OEM for the qualify buyer.We can make the products according to customer personal requirement.

    Q: How about the quality of the managements ?
    A: We have a complete quality control system , all of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE we could send the certification test of our company to you.

    Q: How about your after-sale service?
    A: After sending, we will track the products for you , until you get the products.
    When you got the goods, test them, and give me a feedback.
    If you have any questions about the problem, contact with us, we will offer the solve way for you.

    Quality High Temperature UV DOAS Flue Gas Monitoring System 0.1ppm Resolution For SO2 NO NH3 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Zetron Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)