Sign In | Join Free | My himfr.com
Home > Flue Gas Analyzer >

PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO

    Buy cheap PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO from wholesalers
     
    Buy cheap PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO from wholesalers
    • Buy cheap PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO from wholesalers
    • Buy cheap PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO from wholesalers
    • Buy cheap PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO from wholesalers

    PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO

    Ask Lasest Price
    Brand Name : Zetron
    Model Number : PTM600FG
    Certification : CE
    Price : USD 890/set - 7298/set
    Payment Terms : T/T, Western Union, MoneyGram, D/P, D/A, L/C
    Supply Ability : 1000 SET / week
    Delivery Time : 1-10 work days
    • Product Details
    • Company Profile

    PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO

    PTM600FG 5 Gas Automotive Exhaust Emission Analyzer for CO CO2 O2 HC, NO


    OVERVIEW

    A 5 gas exhaust gas analyzer is a device that measures the emissions from various engines, including those in forklifts, grinders, power tools, vintage cars, motorcycles, automobiles, and small gasoline engines like portable generators. Gas detection is crucial in these analyzers, with 5 Gas Analyzers being a popular choice for detecting the most important gas combination: carbon monoxide (CO), carbon dioxide (CO2), nitrogen oxides (NOx), oxygen (O2), and hydrocarbons (HC). By analyzing the exhaust gas composition, these devices provide valuable insights into engine performance, efficiency, and potential issues that may affect operation and cause toxic gas inhalation. Utilizing a small engine exhaust gas analyzer ensures proper functioning and safety through accurate gas detection.


    PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO


    FEATURES & BENEFITS

    · Temperature and humidity measurement function
    · 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)
    · High temperature sampling and cooling filter handle
    · High temperature humidity pretreatment system· External remote sampling pump
    · Multiple humidity dust filter· CD-ROM (upper level computer communication software)
    · SD card storage
    · USB disk storage
    · External mini wireless infrared printer
    · Built-in mini printer
    · Wireless data communications: RS232, infrared communication, automatic recognition


    SPECIFICATION

    Gases to be detected

    O2: Electrochemical sensor, 0-30%VOL, 0.01%VOL resolution
    CO: NDIR sensor, 0-15%, 0.01%Vol resolution
    CO2: NDIR sensor, 0-20%VOL, 0.01%VOL resolution
    NOx: Electrochemical sensor, 0-2000ppm, 1ppm resolution
    HC : NDIR sensor, 0-5000ppm, 1ppm resolution

    Application scenariosAll the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical,
    environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
    Detection range0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
    Resolution0.01ppm or 0.001ppm (0 ~ 10 ppm);
    0.01ppm (0 ~ 100 ppm),
    0.1ppm (0 ~ 1000 ppm),
    1ppm (0 ~ 10000 ppm or more),
    0.01 mg/l (0 ~ 200 mg/l),
    0.1% LEL,
    0.01%,
    0.001% Vol
    Detection principleElectrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
    Sensor service lifeElectrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years;
    catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
    Allowable error≤±2% F.S (other or higher precision levels can be customized)
    Linearity≤±2%Repeatability≤±2%Uncertainty≤±2%
    Response timeT90≤20 secondsRecovery time≤30 seconds
    Working environmentTemperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
    Sample gas temperature-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
    Temperature and humidity measurementOptional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
    Power supply3.6VDC, 10000mA high capacity rechargeable polymer battery
    Display mode3.5-inch high-definition color screen
    Detection modeBuilt-in pump-suction type measurement, and flow rate at 800 ml / min. Calibration flow rate should be greater than 800 ml / min,
    three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
    Alarm modeIt is possible to set as sound & light alarm, vibration alarm, turning off the alarm.
    Communication interfaceUSB (charging and communication), optional: RS232, infrared communication, automatic recognition
    Data storageStandard configuration is the data storage capacity for 100, 000 entries; SD card storage and USB disk storage functions are optional configuration.
    Protection levelIP66
    Explosion-proof typeIntrinsically safe type
    Explosion-proof markExia II CT6
    Exterior dimensions230×210×120 mm (L×H×W)
    Weight2.5Kg
    Standard accessoriesManual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case,
    built-in humidity dust filter, 0.4 meter stainless steel sampling handle (1 meter of hose, with dust filter, not retractable)
    Optional items
    Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1meter), external remote sampling pump, high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, CD-ROM (upper level computer communication software), external mini wireless infrared printer, built-in mini printer, SD card storage, USB disk storage, wireless data communications.

    PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NOPTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NOPTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NOPTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NOPTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NOPTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NOPTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO


    APPLICATION


    All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.


    Quality PTM600FG 5 Gas Automotive Exhaust Emission Analyzer For CO CO2 O2 HC NO for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Zetron Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)