    Ask Lasest Price
    Brand Name : Alphasense
    Model Number : H2S-B4
    Certification : CE
    Payment Terms : L/C, D/A, D/P, T/T
    • Product Details
    • Company Profile

    Zetron H2S 4 Electrode Hydrogen Sulfide Gas Sensor H2S-B4

    H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) Description
    Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology.
    Sensors are available in the following sizes:
    A: 20mm diameter, the industry standard size for portable gas detectors
    B: 32mm diameter package, the best choice for fixed site applications
    D: miniature, with proven long-term performance. Sensors for the next generation of portable gas detectors
    With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S.

    H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) PERFORMANCE
    SensitivitynA/ppm at 2ppm H2S1450 to 2150
    Response timet90 (s) from zero to 2ppm H2S< 55
    Zero currentnA in zero air at 20℃-250 to 200
    Noise*±2 standard deviations (ppb equivalent)1
    Rangeppm H2S limit of performance warranty100
    Linearityppb error at full scale, linear at zero and 40ppm H2S< ±4
    Overgas limitmaximum ppm for stable response to gas pulse200
    * Tested with Alphasense ISB low noise circuit
    H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) LIFETIME
    Zero driftppb equivalent change/year in lab air< ±100
    Sensitivitydrift % change/year in lab air, monthly test< 20
    Operating lifemonths until 50% original signal (24 month warranted)> 24
    H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) ENVIRONMENTAL
    Sensitivity @ -20℃(% output @ -20°C/output @ 20℃) @ 2ppm H2S77 to 90
    Sensitivity @ 50℃(% output @ 50°C/output @ 20℃) @ 2ppm H2S100 to 110
    Zero @ -20℃nA change from 20℃50 to 60
    Zero @ 50℃nA change from 20℃-120 to -160
    H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) CROSS SENSITIVITY
    NO2 sensitivity% measured gas @ 5ppm NO2< -10
    Cl2 sensitivity% measured gas @ 5ppm Cl2< -12
    NO sensitivity% measured gas @ 5ppm NO< 12
    SO2 sensitivity% measured gas @ 5ppm SO2< 20
    CO sensitivity% measured gas @ 5ppm CO< 3
    H2 sensitivity% measured gas @ 100ppm H2< 0.5
    C2H4 sensitivity% measured gas @ 100ppm C2H4< 0.1
    NH3 sensitivity% measured gas @ 20ppm NH3< 0.1
    CO2 sensitivity% measured gas @ 5% CO2< 0.1
    H2S-B4 Hydrogen Sulfide Sensor (H2S Sensor) KEY SPECIFICATIONS
    Temperature range-30 to 50
    Pressure rangekPa80 to 120
    Humidity range% rh15 to 90
    Storage periodmonths @ 3 to 20℃ (stored in sealed pot)6
    Load resistorΩ (ISB circuit is recommended)33 to 100
    Weightg< 13

    Matched Transmitter board for H2S-B4 H2S Sensor
    Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
    The Individual Sensor Board (ISB) is designed for use with the Alphasense B4 family of four-electrode gas sensors. This potentiostat provides a dual channel voltage output.
    A low noise bandgap provides the bias voltage for NO sensors and the ISB can measure both oxidising (CO, H2S, SO2 and NO) and reducing (O3 and NO2) gases.
    The ISB is configured for specific sensors: NO, NO2, O3 and CO / H2S / SO2 .
    Designed for low power applications, the ISB requires 3.5 to 6.4 stable DC supply at only 1mA.